Methodology · immutable published version
ReChar Methodology for Crop-Residue Gasification, Useful Heat, Fuel Displacement, Livestock Integration, and Biochar-to-Soil Outcomes
Demonstration Version 2.0. Lotus Fire Gasifier is the first qualified technology family, not the entire methodology name. Comparable gasifiers may be admitted after separate qualification. Digital assets arise only after post-impact PoC, validation, legal review, and registrar determination.
Controlling chain
Eligible biomass → qualified technology → commissioned unit → measured cycle → useful heat → evidenced counterfactual displacement → biochar batch → livestock pathway → organic-material batch → soil application → measured agricultural outcome → lifecycle deductions → PoC → validation → legal review → registrar → Negatrope → instrument
Outcome schedules (separate)
- USEFUL-HEAT
- FOSSIL-GAS-DISPLACEMENT
- WOOD-FUEL-DISPLACEMENT
- RESIDUAL-BIOMASS-UTILISATION
- QUALIFYING-BIOCHAR
- BIOCHAR-LIVESTOCK-USE
- BIOCHAR-SOIL-PLACEMENT
- DURABLE-BIOCHAR-CARBON
Do not create an unsupported composite impact score. Wood and LPG displacement are alternative, not additive, for the same heat.
Source evidence (provenance)
The Lotus Fire Gasifier — Performance and Discussion
Alli Devlin · student_thesis
Historical performance observations for Lotus configurations; post-run CO risk while hot char exposed
Not eligible as default issuance factors without formal methodology adoption of specific parameters
Eligible for calculation defaults: no
Thesis Alli Devlin
Alli Devlin · student_thesis
Thermal-use vs resource-recovery efficiency distinction
Historical research values only
Eligible for calculation defaults: no
Designer-reported Lotus 150 nominal output
Paul Olivier / designer materials · manufacturer_spec
7 kW nominal thermal rating
Not useful delivered heat; not registrable default
Eligible for calculation defaults: no
Technology families & models
Lotus Fire Gasifier family LOTUS-FIRE
First qualified technology family under RC-CRG-POC-001. Comparable gasifiers require separate qualification.
- Nominal thermal output
- 7.00 kW (designer-reported)
- Loose runtime (central)
- 35.0 min
- Pellet runtime (central)
- 150.0 min
- Charge mass range
- 0.900–1.200 kg
- Historical char yield
- ~47% (research — not default)
- Registrable reference values?
- No
All reference values are source-derived. Do not use as registrable defaults.
Open Lotus 150 model page →